Switching frequency selection is actually a tradeoff, and follows the below guidelines:
  1. Lower frequency (Eg 30kHz) means bulkier magnetics and capacitors; Higher frequency (Eg 1Mhz)) means smaller parts, hence more compact PSU.
  2. Stay away from exact 150kHz as this is the low end of any EMI compliance; So, if your frequency happens to be exactly 150kHz, then your PSU will be a strong emitter; For many commercial low cost PSUs, 100 KHz has been used for many years, which is why many inductors and capacitors are specified at 100kHz.
  3. Higher frequency >/= 1MHz converters provide for better transient response. Obviously, the control IC should be capable of supporting. There are plenty of resonant converters available.
  4. Higher frequency results in higher switching losses; To control that, you will need faster switching FETs, Diodes, capacitors, magnetics and control ICs.
  5. Higher frequency MAY result in more broadband noise; its not always true, since noise can be controlled by good PCB layout and good magnetics designs.

Board power DC/DC converters are commonly built using 1MHz switchers.
Chassis power Telecom/Server PSUs seem to stay with 100-300KHz range.

Manufacturers are able to achieve exceptional density by virtue of High frequency resonant topologies, but they have to achieve high efficiencies too; Else, they will generate so much heat that they cannot meet UL/IEC safety requirements.
In some cases, they will leave the thermal problem to the user.  Usually, the first few paragraphs of any reference design discusses the tradeoffs.

Post a Comment:

    
Calculate (2 * 4) =

You may also like:

We are frequently changing tap position of Unit station transformer due to voltage problem. What are the impacts on transformer life and is there any solution to minimize this?
The noise level created by the motor at any speed is in a fixed environment, take two motors same HP, Speed, Enclosure, and the applied voltage could be a factor of the noise, the installed conditions of a ...
This could be internal corona discharge. The switchgear should be de-energized and closely examined. That means pump out the SF6 and take it apart. Examine all insulating components. Especially if the sound ...
The affection on variable frequency drive life in the control loop circuit is the power part, the buffer capacitor in smoothing capacitor and IPM board. The ripple current pass the capacitor is a fixed value ...
You know standards for the electronic industry have been around for decades, so each of the interfaces we have discussed does have a standard. Those standards may be revised but will still be used by all ...
Gozuk Service Gozuk Blog: all about electric motor control & drives industries development in energy saving applications.

Featured

Like pumps, fans consume significant electrical energy while serving several applications. In many plants, the VFDs (variable ... energy consumedA frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a ... Motor starter (also known as soft starter, motor soft starter) is a electronic device integrates soft start, soft stop, ... Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the ... Soft Starter reduces electric motor starting current to 2-4 times during motor start up, reduces the impact to power grid during ...

In Discussion