The owner of the system should provide clear requirements of what the system should do and should define what constitutes "maintainability" of the system. This places a burden on the owner of the system to consider the full life-cycle of the system.

1. You need good design documentation.

2. All source code should be well-documented.

3. Coders should be trained on the techniques used and mentored,

4. The use of "templates" helps ensure that coders and maintenance alike are familiar with routine functions.

5. The HMI should provide clear indication of faults and interlocks.

6. The HMI should provide clear indication of equipment statuses.

7. Any code that is hidden must "work as advertised". This means that it must be completely and unambiguously documented for all inputs, outputs, statuses, and configurations. It must be thoroughly tested and warranted by the vendor,

8. All code should be well-tested. (I have found that the first line of defense is to simply read the code!)

Post-Startup
1. The owner should have a change-control procedure to manage modifications.

2. All users and maintenance support personnel should have adequate training. Training needs to be periodically refreshed as it can become stale through lack of use.

Post a Comment:

    
Calculate (3 - 4) =

You may also like:

I tell customers that at least 50% of the design effort is the layout and routing by someone who knows what they are doing. Layer stackup is very critical for multiple layer designs. Yes, a solid design is ...
You can build it all in MagNet using the circuit position controlled switch. You will have to use motion analysis in order to use the position controlled switches. You can also use the back EMF information to ...
PG is short for Pulse Generator, generally it is used for measuring rotational speed. The most common PG card is optical encoder. PG card is a part of vector variable frequency drive, to convert the encoder ...
The noise level created by the motor at any speed is in a fixed environment, take two motors same HP, Speed, Enclosure, and the applied voltage could be a factor of the noise, the installed conditions of a ...
We are frequently changing tap position of Unit station transformer due to voltage problem. What are the impacts on transformer life and is there any solution to minimize this?
Gozuk Service Gozuk Blog: all about electric motor control & drives industries development in energy saving applications.

Featured

Like pumps, fans consume significant electrical energy while serving several applications. In many plants, the VFDs (variable ... energy consumedA frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a ... Motor starter (also known as soft starter, motor soft starter) is a electronic device integrates soft start, soft stop, ... Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the ... Soft Starter reduces electric motor starting current to 2-4 times during motor start up, reduces the impact to power grid during ...

In Discussion