VFD maintenance
Home » Blog » VFD maintenance » VFD overcurrent trip during acceleration/deceleration

VFD overcurrent trip during acceleration/deceleration

First, we should know it's caused by loads or itself. If it's the variable frequency drive problem, we can check the trip current from the VFD operation history, to see if the current exceeds the VFDs rated current or electronic thermal relay settings value. If three-phase voltages and currents are balanced, we should consider overload or sudden change situations, such as motor stall. If the load inertia is big, we should extend the acceleration time appropriately, this is suitable for a good VFD. If the trip current is within the variable frequency drive rated current or electronic thermal relay setting range, then it maybe the IPM module or relevant parts failure. In this case, we can measure the variable frequency drive output terminals (U, V, W), and resistance of the P, N terminals on DC side to determine whether the IPM module damaged or not. If the module is good, then we can know it is the drive circuit trouble. If IPM module overcurrent or ground wire short circuit causes the VFD trip in deceleration, generally it's the top half-bridge module or drive circuit fault; If IPM module overcurrent during acceleration, then it is the next half-bridge module or drive part fault. For such failures, mostly it's the external dust entering the variable frequency drives or environment moisture.

Post a Comment:

    
Calculate (3 - 2) =

You may also like:

The term creepage distance is specifically associated with porcelain insulators used in the Air Insulated substations. Insulator surface attracts dust, pollution (in industrial areas) and salt (along the sea ...
The first question would have to be - why do want to do it? If the data already exists in one location that is accessible by all parts of the program, why are you going to use up more PLC memory with exactly ...
Variable frequency drive cooling system mainly includes heat sinks and cooling fans, wherein the cooling fan service life is short. The fan generates vibration, noise increases and finally stops when ...
You know standards for the electronic industry have been around for decades, so each of the interfaces we have discussed does have a standard. Those standards may be revised but will still be used by all ...
The affection on variable frequency drive life in the control loop circuit is the power part, the buffer capacitor in smoothing capacitor and IPM board. The ripple current pass the capacitor is a fixed value ...
Gozuk Service Gozuk Blog: all about electric motor control & drives industries development in energy saving applications.

Featured

Like pumps, fans consume significant electrical energy while serving several applications. In many plants, the VFDs (variable ... energy consumedA frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a ... Motor starter (also known as soft starter, motor soft starter) is a electronic device integrates soft start, soft stop, ... Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the ... Soft Starter reduces electric motor starting current to 2-4 times during motor start up, reduces the impact to power grid during ...

In Discussion