Q: Three Phase Transformer Phase Angle and Magnitude Distortion due to Unsymmetrical Core Reluctance Seen by Each Phase

In 3 leg three phase transformer, do we get some phase voltage magnitude and angle change due to un-symmetrical reluctance seen by every different phases? The phase at the middle leg is not distorted because fluxes come from both rear legs equally in magnitude. But voltage and angle of rear legs change somewhat because the other two phases' flux come to rear legs in different magnitudes. So this distorts both magnitude and angle of voltage.

Is there a such thing? And how much is this effective?

A: The manufacturer of the transformer should provide a hysteresis curve of the transformer magnetic characteristics with its technical data. The magnetic and electrical flux contributes to the internal impedances of the transformer core and its windings.

Post a Comment:

    
Calculate (1 + 7) =

You may also like:

Its beneficial to opt for the AC Drives as it supports SLVC [ VFD gives almost servo-like torque at low rpms if you give it encoder feedback ], multiple motors can be accessed, torque requirement can be met if ...
Variable frequency drive is capable to smoothly starting AC motors (ramp from 0 up to 100% of the load) as well as the energy saving will be achieved, accordingly. Also may I confirmed that VFD also acting as ...
Before you attempt to dissipate causative factors of harmonics verbally, you take a look at several studies done by NEMA regarding such, and look into variable frequency drive (VFD) a bit better. You can view ...
For a DC Motor Armature, There is a simple method of determining the condition of the Armature. Drop Test Method: Give a DC Voltage across the commutator Segments for one pole pitch area from a Power supply ...
A frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a variable-frequency, variable-voltage output to enable precise motor speed control. Many ...
Gozuk Service Gozuk Blog: all about electric motor control & drives industries development in energy saving applications.

Featured

Like pumps, fans consume significant electrical energy while serving several applications. In many plants, the VFDs (variable ... energy consumedA frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a ... Motor starter (also known as soft starter, motor soft starter) is a electronic device integrates soft start, soft stop, ... Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the ... Soft Starter reduces electric motor starting current to 2-4 times during motor start up, reduces the impact to power grid during ...

In Discussion