Figure out variable speed drives failures

If there is frequent current-limitation or overcurrent alarm during the variable speed drive running, we should check the loads and inverter IGBT module is normal or not, if its good, then the failure is the Hall magnetic compensation current sensor damaged on the control circuit of the variable speed drive. Hall magnetic compensation current sensor is a device to measure the current value of sinusoidal and non-sinusoidal periodic, which can truly reflect the real current waveform, to provide a control and protection signal to the variable speed drive. Generally, this device in variable frequency drive mostly is Swiss company LEM LA series components, LA Series Hall current sensor magnetic compensation can be divided into three and five terminals, for different variable speed drives capacity, the Hall current sensor magnetic compensation also is difference.

Electronic components are very sensitive to static electricity, it will cause electronic components soft breakdown and then cause the circuit board cannot work. So we should be careful when we replace the circuit board, and ensure wearing grounding wrist strap before working, make sure the strap ground directly and human body is at zero potential, in order to prevent body's electrostatic damage to the circuit board. If there is no grounding wrist strap, we should touch the variable speed drive metal cabinet before replacing the circuit board, to ease static electricity through the variable frequency drive enclosure.

Post a Comment:

    
Calculate (5 + 7) =

You may also like:

In bushing insulation test there are three major current elements which any of those could affect the test result. These current elements are Capacitive current, leakage current and creepage current. In Tan ...
Generally, variable frequency drive contains two components: rectifier and inverter. The rectifier converts incoming AC power to DC power, then the inverter converts DC power to the desired frequency AC power. ...
We have system which is connected to 16kV/2.4 utility transformer (delta on secondary) and we are using 2.kV/480V transformer for loads after 2000ft. Utility wants to protect against ground fault in the ...
The efficiency of an induction motor is determined by intrinsic losses that can be reduced only by changes in motor design. Intrinsic losses are of two types: fixed losses - independent of motor load, and ...
If I had a "critical" operation with a double-action cylinder, hydraulic or pneumatic, I'd put proximity sensors on both ends of travel, typically with small metal "marker" on the shaft. Each input "in series" ...
Gozuk Service Gozuk Blog: all about electric motor control & drives industries development in energy saving applications.

Featured

Like pumps, fans consume significant electrical energy while serving several applications. In many plants, the VFDs (variable ... energy consumedA frequency inverter controls AC motor speed. The frequency inverter converts the fixed supply frequency (60 Hz) to a ... Motor starter (also known as soft starter, motor soft starter) is a electronic device integrates soft start, soft stop, ... Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the ... Soft Starter reduces electric motor starting current to 2-4 times during motor start up, reduces the impact to power grid during ...

In Discussion